CO-Sensor (A1) | |
---|---|
Measurement range | 0...1.000 ppm |
Accuracy | ±5 ppm + max. ±5% f. mv (at 20°C, 50% r.H.) |
Temperature dependency | ±5 ppm / K |
Response time (t90) | < 5 min |
Long term stability | ±1% FS/year |
Sensor | Electrochemical gas sensor |
CO2-Sensor (A2, A22, A23) | |
Measurement range A2 | 0...10.000 ppm |
Measurement range A22 | 0...20.000 ppm |
Measurement range A23 | 0...50.000 ppm |
Accuracy | ±50 ppm + 2% v. MW at 0-2000 ppm, ±50 ppm + 3% v. MV at 0-5000 ppm, else ±100 ppm + 5% v. MV (at 20°C, 1013 mbar, auto calibration ON) |
Temperature dependency | ±5 ppm / K |
Druckabhängigkeit | compensated if option "air pressure sensor" is selected, else 1.6% of the meassurement value / kp difference to 1013mbar |
Response time (t90) | < 1 min |
Long term stability | ±1% FS/year |
Sensor | Nondispersive infrared sensor (NDIR) |
Automatic calibration | The automatic drift compensation takes place in the interval of 7 days. This ensures an excellent long-term stability. The device must be supplied with fresh air within this interval (during continuous operation) for at least 10 minutes. This function can |
Manual calibration | Manual adjustment to 400 ppm can be executed via registry-command. |
Oxygen sensor (A31, A32) | |
Measurement range oxygen A31 | 0…25% vol. |
Measurement range oxygen A32 | 0…100% vol. |
Accuracy | ±5 µg/m³ + max. ±4% FS (@ 20°C, 45% r.H., 1013 mbar) |
Temperature dependency | ±1% FS / 10 K |
Long term stability | ±0,2% FS/year at auto calibration ON |
Response time (t90) | <1s |
Air quality sensor for mixed gas -VOC (A4) | |
Measurement range VOC | 0-100% (good / bad air quality, referring to the calibration gas) |
Accuracy | ± 10% FS (at 20°C, 50% r.H. and auto-calibration ON) |
Temperature dependency | ±0,2% FS/K |
Response time (t90) | < 1 min |
Long term stability | ±5% FS/year (auto-calibration ON) |
Sensor | metal oxide VOC-sensor |
Automatic calibration | The automatic drift compensation takes place in the interval of 7 days. This ensures an excellent long-term stability. The device must be supplied with fresh air within this interval (during continuous operation) for at least 10 minutes. This function can |
Manual calibration | Manual zeropoint can be setted via registry-command to 10% |
Sensitivity | Sensitivity can be varied at three levels via registry-command to 10% |
Particulate Matter Sensor PM2.5/PM10 (A51) | |
Measurement range particulate matter | 0 μg/m³ ... 1000 μg/m³ |
Accuracy | ±5 µg/m³ + max. ±4% FS (@ 20°C, 45% r.H., 1013 mbar) |
Temperature dependency | ±1% FS / 10 K |
Long term stability | ±1% FS/year |
Response time (t90) | <1s |
Flow transducer (F11 or F12 - with pendulum sensor, mounting flange within scope of delivery) | |
Measuring principle | calorimetric measuring method |
Measurement range flow F11 | 0...5 m/s |
Measurement range flow F12 | 0...20 m/s |
Calculation air flow F11 | 0-50.000 m³/h, formula and parameters via registry |
Calculation air flow F12 | 0-200.000 m³/h, formula and parameters via registry |
Accuracy | ±0,3 m/s + max. ±4% FS (@ 20°C, 45% r.H., 1013 mbar) |
Temperature dependency | ±1% FS/ 10 K |
Long term stability | ±1% FS/year |
Response time (t90) | <1s |
operating range F11 | 0,3...5 m/s |
operating range F12 | 0,3...20 m/s |
Humidity / temperature transducer (H1T1 or H2T1 - heated temporarily or permanently) | |
Measurement range r.H. | 0-100% r.H. |
Accuracy humidity | ±3% r.H. (30-70% r.H., else ±5% r.H., at 20°C) |
Measurement range temperature | -20°C...50°C |
Accuracy temperature | ±0,5 K |
Calculated thermodynamic values | dew point temperature, abs. humidity, air fuel ratio, enthalpy, wet bulb temperature, vapour pressure |
Long term stability | ±1% FS/year |
Sensors | Combined humidity and temperature sensor |
Sensor protection high-humidity range H1T1 | condensation protection by heating function at more than 95% r.H. ( holding function of the meassured values during heating function). |
Sensor protection high-humidity range H2T1 | Kondensationsschutz durch Dauerheizung ca. 3 K über Umgebungstemperatur |
Flow rate | < 2 m/s |
Motion Sensor (M1) | |
Measurement range motion | motion yes/no, apex angle 90°/110° on 360° range, reach 10 m |
Response time (t90) | < 1 s |
Sensor | infrared motion sensor MTS 10/360, photodiode |
Pressure Sensor (P2 oder P22 oder P23) | |
Measurement range pressure P2 | -100...+100 Pa |
Measurement range pressure P22 | -500...+500 Pa |
Measurement range pressure P23 | -5000...+5000 Pa |
Calculation air flow P2 | 0...4.000 m³/h of the differential pressure uo to 100Pa, formula and parameters via registry |
Calculation air flow P22 | 0...20.000 m³/h of the differential pressure uo to 500Pa, formula and parameters via registry |
Calculation air flow P23 | 0...200.000 m³/hof the differential pressure uo to 5000Pa, formula and parameters via registry |
Accuracy | Difference pressure |
Temperature dependency | Difference pressure |
Linearity inaccuracy | Difference pressure / Air Pressure |
Offset | can be set at the registry |
Output attentuation | can be set at the registry |
Pressure resistance | 5-times of measurement range |
Manual zero-point adjustment | Manual zero-point adjustment can be executed |
Air Pressure Sensor (P4) | |
Measurement range atmospheric / barometric pressure | 500-1150 mbar |
Accuracy | ±3 mbar (at 20°C) |
Temperature dependency | 1 mbar / 10 K |
Linearity inaccuracy | ±1% FS |
Offset | can be set at the registry |
Output attentuation | can be set at the registry |
General | |
Supply voltage | 24V DC +/-5% |
Current consumption | typically 100 mA, (depending on MODBUS parameters and selected backlight) plus around 20ma/sensor |
Digital output | Modbus RTU |
Electrical connection | push-in terminal, no tools required, time-saving |
Display | programmable display at 3 levels, customer-specific interfaces optional |
Housing | Polycarbonate PC UL 94 V0 with hinge locks, color light grey |
Cable gland | Cable connection 12mm with stain relief |
Dimensions | Housing |
Alarm transmitter (piezo) | freely programmable, volume approx. 85db at a distance of 10cm |
Protection type Housing/electroic | IP65 (IP20 at option particulate matter and/or CO2) |
Protection type sensor attachments | IP30 |
Protection class | III |
Sensor protection | (1) r. / Temp, VOC, CO2 |
Working- and Storage temperature | -20...+50°C |
Range of application | Ambient air monitoring, pollution-free, non-condensing air up to max. 98% r.H. (except harmful gases in accordance with sensor specifications) |
Attachments at the device | V2A tubes and/or V2A sinter filter |
Option clamping connectors / screw connectors | Steel M12 industrial standard |
special features | When calculating different sizes, depending on the selected sensor configuration, air pressure, air density, etc. are included. If these values are not available internally from sensors, they can be entered by the Modbus master into the corresponding regi |