Lambda-Transmitter LT1, Lambda-Transmitter LT1 Lamtec, Thiết bị đo O2 Lambda-Transmitter LT1, Đại lý Lamtec tại Việt Nam
Đại lý Lamtec tại Việt Nam
- High-end O2 measuring
- Fully automatic calibration with ambient air
- Applicable up to 1400 °C
- TUV approval for emission monitoring
- Easy to use and low-maintenance
Preciseness: | ±0,2 Vol. % O2 after balancing on air value 21 % O2 (with Lambda-probe LS1) |
Setting time: | <20 s on 90 % of final value (T90) (with Lambda probe LS1 type 650 R 0001 and 450 mm MEV) |
Failure impact Deviation by temperature |
1 % of measurement value / 10 K housing temperature Lambda probe LS1, |
Failure impact Deviation by pressure |
1,3 % of measurement value / 10 mbar pressure change / pressure compensation optional |
Ambient temperature - operation - transport and storage |
0°C...+60°C |
Supply voltage | 230V AC and 115 V AC +10% / -15%, 48Hz...62Hz To be used in grounded network lines only! |
Resolution | 0,01% over the whole range |
Time for being ready with LS1 | 1...2 hours after "POWER ON" |
Approvals: |
SIL 1 Confirmation:
|