LCA-4TR-50-1210-AP-156579, LCA-4TR-50-1210-AP-156579 Euchner, Đại lý Euchner tại Việt Nam
Controls and indicators
LED indicator | yes |
Electrical connection ratings
Cascadable | no |
Current consumption | 400 mA |
Muting possible | in combination with external sensors and an evaluation unit |
Operating voltage DC | 24 V DC -20% ... +20% |
Receiver power consumption | 2 W |
Transmitter power consumption | 1 W |
Mechanical values and environment
Ambient temperature | -30 ... +55 °C |
Connection | Plug connector M12 (5-pin transmitter/8-pin receiver) |
Degree of protection | IP65/IP67 |
Dimensions | 28x30 mm |
Height of the protective field | 1210 mm |
Height of the sensor | 1263 mm |
Installation orientation | any |
maximum length of connecting cables | 100 m |
Number of safety outputs | 2 static, self-monitoring PNP safety outputs |
Range of the protective field | 20000 mm |
Reaction time | 6 ms |
Resolution | 50 mm |
Reliability values according to EN ISO 13849-1
ESPE type | 4 |
Mission time | 20 y |
Performance Level | PL e |
PFHd | 1.41x10-8 |
Safety Integrity Level | SIL 3 / SILCL 3 |