Flowline Vietnam, Flowline-Vietnam, Cảm biến đo mức Flowline, Cảm biến siêu âm Flowline, Đại lý Flowline tại Việt Nam

Đại lý Flowline tại Việt Nam

Liquid & Solids Level Transmitters

Reflective Ultrasonic Sensors | Liquids | General Purpose & Intrinsically Safe

  EchoPod UG01 UG03 Reflective Ultrasonic Multi-Function Liquid Level Transmitter EchoPod UG06 UG12 Reflective Ultrasonic Liquid Level Transmitter EchoTouch US01 US03 Reflective Ultrasonic Liquid Level Transmitter EchoTouch US06 US12 Reflective Ultrasonic Liquid Level Transmitter
Series UG01-03 UG06-12 US01-03 US06-12
Classification General purpose General purpose Intrinsically safe Intrinsically safe
Media Liquids Liquids Liquids Liquids
Application Day tank, skid or machine, cooling tower, IBC or drum, process tank, small waste sump Bulk storage, neutralization tank, clarifier, large waste sump Day tank, skid or machine, IBC or drum, process tank, small waste sump Bulk storage, neutralization tank, clarifier, large waste sump
Condensation Yes Yes Yes Yes
Range 9.8' (3m) 39.3' (12m) 9.8' (3m) 39.3' (12m)
Output 4-20 mA + (4) SPST relays 4-20 mA 4-20 mA 4-20 mA
Display No Yes No Yes
Configuration WebCal software Push button, WebCal software WebCal software Push button, WebCal software
Termination Cable Conduit Cable Conduit
Mount 2" NPT (G) 2", 3" NPT (G) 2" NPT (G) 2", 3" NPT (G)
Temperature -40º F. (-40º C.) to 176º F. (80º C.) -40º F. (-40º C.) to 176º F. (80º C.) -40º F. (-40º C.) to 176º F. (80º C.) -40º F. (-40º C.) to 176º F. (80º C.)
Max. pressure 30 PSI (2 bar) 30 PSI (2 bar) 30 PSI (2 bar) 30 PSI (2 bar)
Trans. material PVDF PVDF PVDF PVDF
From        
 

Ultrasonic Sensors | Liquids | General Purpose

 
Series DX10 DL10 DL14 DL24 LU23-29 LU80-84
Classification General purpose General purpose General purpose General purpose General purpose General purpose
Media Liquids Liquids Liquids Liquids Liquids Liquids
Application Chemical feed, skid or machine, IBC or drum Chemical feed, skid or machine, IBC or drum Chemical feed, skid or machine, IBC or drum Day tank, skid or machine Bulk storage, day tank, waste sump Bulk storage, day tank, waste sump
Condensation Minimal Minimal Minimal Minimal Minimal Minimal
Range 49.2" (1.25m) 49.2" (1.25m) 49.2" (1.25m) 9.8' (3m) 32.8' (10m) 32.8' (10m)
Output Voltage or frequency 4-20 mA 4-20 mA + (4) SPST relays 4-20 mA + (4) SPST relays 4-20 mA 4-20 mA
Display No No No No No Yes
Configuration WebCal software WebCal software WebCal software WebCal software WebCal software Push button
Termination Cable Cable Cable Cable Cable Conduit
Mount 1" NPT (G) 1" NPT (G) 1" NPT (G) 1" NPT (G) 1", 2" NPT (G) 1", 2" NPT (G)
Temperature 20º F. (-7º C.) to 140º F. (60º C.) 20º F. (-7º C.) to 140º F. (60º C.) 20º F. (-7º C.) to 140º F. (60º C.) 20º F. (-7º C.) to 140º F. (60º C.) -4º F. (-20º C.) to 140º F. (60º C.) -4º F. (-20º C.) to 140º F. (60º C.)
Max. pressure 30 PSI (2 bar) 30 PSI (2 bar) 30 PSI (2 bar) 30 PSI (2 bar) 30 PSI (2 bar) 30 PSI (2 bar)
Trans. material PVDF PVDF PVDF PVDF PVDF PVDF
From            
 

Radar Sensors | Liquids | General Purpose

 
Series LR10 LR15 LR20 LR30
Classification General purpose General purpose General purpose General purpose
Media Liquids Liquids Liquids Liquids
Application Storage Storage Storage Lift station
Process condition Easy Difficult Difficult Difficult
Tank location and material Above grade metal or below grade in any tank material Above or below grade in any tank material Above or below grade in any tank material Below grade in any tank material
Corrosive Yes Diluted Yes Diluted
Range 32.8' (10m) 98.4' (30m) 65.6' (20m) 98.4' (30m)
Output 4-20 mA 4-20 mA 4-20 mA 4-20 mA
Installation Tank adapter or flange Tank adapter or flange Flange Bracket
Mount 1 1/2" NPT 1 1/2" NPT 3", 4" ANSI Bolt
Max. temperature 266° F. (130°C.) 302º F. (150º C.) 302º F. (150º C.) 212º F. (100º C.)
Max. pressure 43.5 PSI (3 bar) 150 PSI (10 bar) 72 PSI (5 bar) Atmospheric
Ant. material PFA 316L 316L & PTFE Nylon
From        
 

Radar Sensors | Liquids | Intrinsically Safe

  EchoPulse LR11 Pulse Radar Liquid Level Sensor EchoPulse LR16 Pulse Radar Liquid Level Sensor EchoPulse LR21 Pulse Radar Liquid Level Sensor EchoPulse LR31 Pulse Radar Liquid Level Sensor
Series LR11 LR16 LR21 LR31
Classification Intrinsically safe Intrinsically safe Intrinsically safe Intrinsically safe
Media Liquids Liquids Liquids Liquids
Application Storage Storage Storage Lift station
Process condition Easy Difficult Difficult Difficult
Tank location and material Above grade metal or below grade in any tank material Above or below grade in any tank material Above or below grade in any tank material Below grade in any tank material
Corrosive Yes Diluted Yes Diluted
Range 32.8' (10m) 98.4' (30m) 65.6' (20m) 98.4' (30m)
Output 4-20 mA with HART 4-20 mA with HART 4-20 mA with HART 4-20 mA with HART
Installation Tank adapter or flange Tank adapter or flange Flange Bracket
Mount 1 1/2" NPT 1 1/2" NPT 3", 4" ANSI Bolt
Max. temperature 266° F. (130°C.) 302º F. (150º C.) 302º F. (150º C.) 212º F. (100º C.)
Max. pressure 43.5 PSI (3 bar) 150 PSI (10 bar) 72 PSI (5 bar) Atmospheric
Ant. material PFA 316L 316L & PTFE Nylon
From        
 

Radar Sensors | Solids | Intrinsically Safe

  EchoPulse LR36 Pulse Radar Solids Level Sensor EchoPulse LR36 LR41 Pulse Radar Solids Level Sensor EchoPulse LR46 Pulse Radar Solids Level Sensor
Series LR36 LR41 LR46
Classification Intrinsically safe Intrinsically safe Intrinsically safe
Media Solids Solids Solids
Application Crusher, transfer station, bin Crusher, transfer station, stockpile, silo, bin Silo
Process dust Minimal Moderate Significant
Range 49.2' (15m) 229.7' (70m) 229.7' (70m)
Output 4-20 mA with HART 4-20 mA with HART 4-20 mA with HART
Installation Bracket or gimbal flange Bracket or gimbal flange Gimbal flange
Mount 1 1/2" NPT, 4" or 5" ANSI 1 1/2" NPT, 4" or 5" ANSI 4" or 5" ANSI
Max. temperature 392º F. (200º C.) 752º F. (400º C.) 752º F. (400º C.)
Antenna type 4" horn 4" or 5" horn 8" or 10" parabola
Ant. air purge No Yes No
Ant. dust shield No Option No
Ant. material 316L 316L with optional PTFE dust shield 316L
From      
 

Guided Wave Sensors | Liquids | General Purpose

 
Series LG10-0 LG10-1 LG11-2
Classification General purpose General purpose General purpose
Media Liquids Liquids Liquids
Application Day tank, skid or machine, IBC or drum, process tank, waste sump Day tank, skid or machine, IBC or drum, process tank, waste sump Bulk storage
Probe type Rod Coaxial Cable
Probe material 316L 316L 316
Tank location and material Above grade metal or below grade in any tank material Above or below grade in any tank material Above grade metal or below grade in any tank material
Dirty, coating or crystallizing liquid Yes No Yes
Range 9.8' (3m) 9.8' (3m) 18' (5.5m)
Output 4-20 mA 4-20 mA 4-20 mA
Mount 3/4" NPT 3/4" NPT 3/4" NPT
Max. temperature 302° F. (150° C.) 302° F. (150° C.) 302° F. (150° C.)
Max. pressure 250 PSI (17 bar) 250 PSI (17 bar) 250 PSI (17 bar)
From