ADV-2110-KBX-4+SI, ADV-2110-KBX-4+SI Gefran, Bộ điều khiển ADV-2110-KBX-4+SI, Đại lý Gefran tại Việt Nam
Model: BWU2535 ASi-3 PROFIBUS Gateway with integrated Safety Monitor, 2 ASi masters ASi-3 PROFIBUS Gateway with integrated Safety Monitor, 2 ASi masters, 4 digital inputs, expandable to max. 62 x 2 channels safe inputs, 4 release circuits (2 x relay outputs and 2 x electronic safe outputs), expandable to max. 16 safe outputs, diagnostic and configuration via RS232 diagnostic interface, duplicate address recognition, ASi fault detector, programming in C optional, IP20 |
Model: BWU2234 ASi-3 PROFIBUS Gateway in Stainless Steel, 2 masters ASi-3 PROFIBUS Gateway in Stainless Steel, 2 ASi masters, 1 power supply for 2 ASi networks, duplicate address recognition, ASi fault detector |
Nr: TD-2/A1/B2/C1 Monitoring and protection equipment for rotating machines Functions Vibration + Phase (with Key phasor) Sensor Type: IEPE Accelerometer or Velomitor Output type: 4÷20 mA TDSP SETUP Software to configure the device included T1-EA/1/1/0/0/0/0/0/0 is obsolete |
Model : LZZBJ9-10C6 Current Transformer Note : báo giá theo nameplate |
HD2010UC/A.Kit2 HD2010UC/A Class 2 Integrating Sound Level Meter and Analyzer Including Accessories and carrying case |
D-R 290 M EC2-10SAE PN: 4007633 Measuring head to monitor the opacity / dust concentration - Meas. ranges: 0-0.1 ... 2.0 ext / 0-20%...100% opacity - compliant with EN 15267 according to type approval - designfor European market, - 24 VDC, 1x 4-20mA, 2x contact NC/NO, 1xRS485, - purge flange: pc d=100 mm, purge air inlet: d=40 mm, incl. rubber seal 120x3x20mm, purge flange with swirler, - for installation in N-Ex area, - incl. 1x M23 connector, 1x USB, 2xconnector for fail safe shutter - hxwxd approx.400x200x400 mm - material: Al paint - Ta:-40...+60 °C, - suitable for measuring path length 1-8 m |
ADV-2110-KBX-4+SI Inverter DRIVE S9O08SI |
Model: RCP5W-RA6C-WA-42P-3-100-P3-X10-A1-B-NM Thiết bị dẫn động |
145-100 DA ACTUATOR MODEL 140 WITH NAMUR ADAPTOR |
Model: DWU-36.W2H.XLT.0.Y Range : 60-240 m3/h |
Model: DWU-36.W1Z.XLT.0.Y Range : 20-80 m3/h |
Model: OnCell 3120-LTE-1-EU Industrial LTE Cat 1 cellular gateway, B1/B3/B8/B20/B28, 0 to 55°C |
Model: PT-7528-24TX-HV-HV IEC 61850-3 managed rackmount Ethernet switch system with up to 28 ports (including 1 slot for a fast Ethernet or Gigabit module), 2 isolated power supplies (88-300 VDC or 85-264 VAC), -40 to 85°C operating temperature |
LJPA1300EA20A00 radio remote control JUMP series Set consisting of: Receiver unit - Version in standard housing (IP65) - Voltage module 48V AC - radio receiver - 20 relays Transmitting unit - 13 function keys (2-stage) - Lateral emergency stop, start / alarm - Carrying strap |
LJPA1300QC20A10 radio remote control JUMP series Set consisting of: Receiver unit - Version for top hat rail mounting (IP20) - voltage module 10-36V DC - radio receiver - 20 relays - External antenna with 5 m cable length Transmitting unit - 13 function keys (2-stage) - Lateral emergency stop, start / alarm - Carrying strap |
Code: 2049526 Description: Printed circuit board |
Code: 2086036 Description: Display module |
Code: HMT310 7C5A1NNA14BPFA1A1 Humidity and Temperature Transmitter Probe code: HMT317 Code Td+Tdf+x With warmed RH probe Wall Plate with Flange Power Supply: Standard (24 VDC) Analog Output (CH1+CH2) Output 4...20mA Channel 1 Td (-40...+100C) Channel 2 Td (-40...+100C) No T-Range Metric Units Connection Cable 5m 8 pin M12 Female, Black User´s Guide HMT310 English HMP307 Probe 2m composite sensor with chemical purge default HUMICAP180RC for warmed HMT317 PPS Grid with Steel Netting No Temperature Probe No Installation Kit Calibration Certificate No Cal. Cert. |
Code: HMT330 3E0A001BCAK100B0AACBAA1 Humidity and Temperature Transmitter Probe 2m; No Temperature Probe Calculations: Code RH+T; No Display Standard (10...35V,24VAC) Analog Output 4...20mA Channel 1 RH (0...100%RH) Channel 2 T (Range See Below) Channel 3: No Analog Outputs Temperature Range 0...+60C Metric Units Cable bushings: Cond Uit Fitting NPT 1/2" No Installation Kit General purpose HUMICAP180R PPS Grid with Steel Netting Duct Installation Kit For HMT333 and HMT337 User´s Guide HMT330 English No PC Accessories No Calibration Contract ISO9001 Calibration No Maintenance Contract |
Code: K21R 132 S4T 5,5kW, 1425rpm, 380V, D, 50 Hz, IM B3 - IP55, Th. cl. 155(F), Duty type S1, Nameplate de/en, Colour system 01 Moderate (KK C2), RAL 7031 blue-grey IEC / EN 60034-1 Limit values to vibration velocity Class A Easy bearing arrangement Balancing with half key Standard documentation |
12,8V/100Ah – Smart Victron lithium battery Technical data: Rated voltage/capacity at 25°C: 12.8V/100Ah Rated energy at 25°C: 1280Wh Number of cycles at 80% DOD: approx. 2500 max. discharge current/sens. Discharge current: 200/100 max. charge current/empf. charge current: 200/50 battery connection: M8 protection class: IP22 NOTE: DANGEROUS GOODS |
Model: TR400 Ziehl Temperature Controller |