DZ01 Permeability Test System is designed and manufactured based on infrared sensor and coulometric sensor conforms to the requirements of ASTM D3985, ASTM F2476, ASTM F1249 and ISO 15106-2. This instrument can be used to measure the oxygen, carbon dioxide, and water vapor transmission rate of barrier materials with high, and medium barrier properties with a wide testing range and high testing efficiency. The instrument is featured with patented design of integrated block consisting of 3 test cells. Equipped with high precision sensors and professional computer-controlled system, the instrument can regulate and control the temperature, humidity and flow rate precisely, which guarantee the testing sensitivity and repeatability of test results. DZ01 is applicable to determination of oxygen, carbon dioxide, and water vapor permeability of plastic films, sheeting, paper, packages and other relative packaging materials in food, pharmaceutical, medical apparatus, consumer goods, photovoltaic and electronic industries, etc.
Technical Specifications
Table 1: Test Parameters Note1
Parameter | Model DZ01 | |
---|---|---|
Test Range (Oxygen, Coulometric sensor ) |
cm3/(m2·day·bar) (Standard) | 0.01 ~ 7500 |
cm3/(m2·day·bar) (Masked) | 0.2 ~ 150,000 | |
cm3/(pkg·day·bar) (Package) | 0.00005~37.5 | |
Test Range (Carbon dioxide, Infrared sensor) |
cm3/(m2·day·bar) (Standard) | 0.25~18,000 |
cm3/(m2·day·bar) (Masked) | 20~360,000 | |
cm3/(pkg·day·bar) (Package) | 0.00125~1800 | |
Test Range (Water Vapor, Infrared sensor) |
g/(m2·day·bar) (Standard) | 0.002 ~ 100 |
g/(m2·day·bar) (Masked) | 0.04~2000 | |
g/(pkg·day·bar) (Package) | 0.00001 ~ 0.5 | |
Test Temperature | °C | 10 ~ 55 |
Accuracy | ±0.1 | |
Test Humidity (RH) | Oxygen | 0%, 5% ~ 95% , 100% |
Carbon dioxide | 0%, 5% ~ 95% , 100% | |
Water Vapor | 5% ~ 95% , 100% | |
Accuracy | ±1% | |
Additional Functions | Package Test (3L Max.) | Optional |
DataShieldTM Note2 | Optional | |
Computer System required by GMP | Optional | |
CFR21 Part11 | Optional |
Table 2: Technical Specifications
Test Chamber | 3 test chambers (all three permeability tests can be performed without changing the film) |
---|---|
Specimen Size | 108 mm X 108 mm |
Specimen Thickness | ≤3 mm |
Standard Test Area | 50 cm2 |
Number of Gas Inlet Channels | 3 |
Carrier Gas | 99.999% High-purity Nitrogen (outside of supply scope) |
Gas flow | 10 - 100 ml /min |
Gas releasing pressure control | 1.5 up to 2 bar (Nitrogen) 1.5 bar (Oxygen, Carbon dioxide) |
Carrier Gas Pressure | ≥0.28MPa/40.6psi |
Port Size | 1/8 inch metal tubing |
Power Supply | 100-240 V, 50-60Hz |