Euchner Vietnam, MGBS-P-L1H-AP-U-R-SA-161565, Công tắc an toàn MGBS-P-L1H-AP-U-R-SA-161565, Đại lý Euchner tại Việt NamLocking modules MGBS-
P-L1-AP-U-R-AZ-SA-159366 (Order No. 159366)
Work area
Repeat accuracy R | |
according to EN 60947-5-2 | 10 % |
Electrical connection ratings
Current consumption | |
IUB | 40 mA |
IIMP | 400 mA |
Degree of contamination (external, according to EN 60947-1) | 3 |
EMC protection requirements | according to EN IEC 60947-5-3 |
Fusing | |
external (operating voltage UB) | 0.25 ... 8 A |
external (solenoid operating voltage IMP) | 0.5 ... 8 A |
Operating voltage DC | |
UUB | 24 V DC -15% ... +15% reverse polarity protected, regulated, residual ripple 5%, PELV |
Power consumption | 6 W |
Rated impulse withstand voltage Uimp | 0.5 kV |
Rated insulation voltage Ui | 50 V |
Safety class | |
EN IEC 61140 | III |
Solenoid duty cycle | 100 % |
Solenoid operating voltage DC | |
UIMP | 24 V DC -15% ... +10% reverse polarity protected, regulated, residual ripple < 5%, PELV |
Switching load | |
according to UL | 24V DC, Class 2 |
Test pulse interval | min. 100 ms |
Test pulses | max. 0.3 ms |
Utilization category | |
DC-13 | 24V 150mA |
Monitoring output OD, OI | |
Output type | p-switching, short circuit-proof |
Output voltage | 0.8xUB ... UB V DC |
Switching current | 1 ... 50 mA |
Safety outputs FO1A / FO1B | |
Discrepancy time | |
both safety outputs | max. 10 ms according to EN IEC 60947-5-3 |
Off-state current Ir | max. 0.25 mA |
Output type | 2 semiconductor outputs, p-switching, short circuit-proof |
Output voltage | |
HIGH U(FO1A) / U(FO1B) | UB-1.5 ... UB V DC |
LOW U(FO1A) / U(FO1B) | 0 ... 1 V DC |
Switching current | |
per safety output FO1A / FO1B | 1 ... 150 mA |
Turn-on time | max. 400 ms |
Mechanical values and environment
Actuating force | 10 N |
Ambient temperature | |
at UB = 24V DC | -20 ... +55 °C |
Approach speed | max. 20 m/min |
Connection | 1 plug connector M12, 8-pin |
Degree of protection | IP67/IP69/IP69K |
Extraction force | 20 N |
Guard locking principle | Closed-circuit current principle |
Installation orientation | Door hinge DIN right |
Locking force Fmax | 3900 N |
Locking force FZh | 3000 N |
Material | |
Switch bracket | Die-cast zinc |
Switch head cover | Die-cast zinc |
Safety switch housing | reinforced thermoplastic |
Mechanical life | 1 x 10⁶ |
Overtravel | 5 mm |
Ready delay | max. 1 s |
Retention force | 20 N |
Shock and vibration resistance | according to EN 60947-5-3 |
Switching frequency | max. 0.5 Hz |
Reliability values according to EN ISO 13849-1
Category | 4 |
Mission time | 20 y |
Performance Level | PL e |
PFHd | 4.1 x 10 -9 |
Miscellaneous
The following applies to the approval according to UL | Operation only with UL Class 2 power supply or equivalent measures; see operating instructions |
Handle modules MGBS-H-BA1A3-R-157543 (Order No. 157543)
Mechanical values and environment
Ambient temperature | -20 ... +55 °C |
Degree of protection | IP65 |
Installation orientation | Door hinge DIN right |
Material | |
Housing | Fiber glass reinforced plastic, nickel-plated die-cast zinc, stainless steel |
Miscellaneous
Additional feature | with automatic lockout mechanism |